A heat pump is a good match for most Oklahoma City winter days and a confusing one on the few really cold nights. It steams, it blows cool air for a few minutes, the thermostat shows AUX or EM, and then the electric bill arrives. Most of that is normal. Some of it is not. This page explains the three ways a heat pump makes heat in a cold snap, sets them against Oklahoma City’s own January figures, and lists the faults that need a contractor.
Oklahoma City Heating connects people with independent local heating and air contractors, who diagnose and repair the system. Your request goes to a contractor who works in your part of the metro.
How a heat pump heats, in plain terms
In heating mode, refrigerant in the outdoor coil soaks up heat from the outdoor air, even cold air, and the compressor carries it inside to the indoor coil. The US Department of Energy explains that a heat pump moves heat rather than burning fuel to make it, which is why it is efficient. It also explains the catch: as the outdoor air gets colder, there is less heat to move, output falls, and the system leans on supplementary heat, usually electric resistance strips in the indoor air handler.

Defrost, auxiliary heat and emergency heat compared
The 1991 to 2020 normals for Will Rogers World Airport put January’s average low at 27.0 degrees and its average high at 49.3. The coldest night of an average January reaches about 11.7 degrees. December and February lows average 29.5 and 30.8. So most heating hours in OKC sit in the range where a heat pump does well, a good number of nights run below freezing with damp air that frosts the coil, and a handful each year are cold enough for the strips to carry real load.
| Normal defrost | Auxiliary heat (AUX) | Emergency heat (EM) | |
|---|---|---|---|
| What starts it | Frost on the outdoor coil, usually below about 40 degrees in damp air | The heat pump cannot keep up, or the thermostat calls for a big jump | Only you, by switching the thermostat to EM |
| What runs | The system briefly reverses to cooling mode to warm the outdoor coil; strips often run to temper the air | Compressor plus electric strips together | Electric strips alone; the outdoor unit is locked out |
| How long | Typically several minutes, then back to heating | As long as the house is behind | Until you switch it back |
| What you see and feel | Steam off the outdoor unit, fan stopped, cool or lukewarm air for a few minutes | Warmer air from the vents | Warm air, outdoor unit silent |
| Typical OKC conditions | Damp nights in the 20s and 30s: the December to February average lows | Mornings after a cold night, and nights near the 11.7 degree average January cold snap | When the outdoor unit has failed or is iced solid |
| Effect on the electric bill | Small | Higher: resistance heat costs more per hour than the heat pump | Highest: strips only, for as long as it is on |
| When it is a fault | Coil stays iced for hours, or defrost every few minutes | AUX on almost all the time above about 35 degrees | Being needed at all, beyond a short bridge to a repair |
Exact switch points vary by make, model and thermostat setup, and your contractor can tell you how yours is set. The pattern is what matters: defrost is short and frequent in damp cold, auxiliary heat shows up on the coldest mornings, and emergency heat is a manual backup for a broken outdoor unit.
Why the bill jumps in a cold snap
In a cold snap three things stack up. The heat pump moves less heat per hour because the outdoor air is colder. The house loses heat faster for the same reason. And the strips, which turn electricity straight into heat, run more to fill the gap. A few nights near the January average low of 12 degrees can show up clearly on the bill. In February 2021, when Oklahoma City fell to minus 14, many heat pumps ran on strips for days.
You can soften this. Avoid big setbacks on a heat pump thermostat in cold weather: raising the set point by several degrees on a cold morning brings on the strips. A thermostat built for heat pumps, with smart recovery, warms the house slowly with the compressor instead. Keep the outdoor unit clear of snow drifts and ice dripping from the eaves.
Faults that need a contractor
Outdoor coil iced solid
A light white frost that clears every so often is normal. A thick block of ice that covers the coil and stays for hours means defrost is not working. Causes include a failed defrost control board, a bad coil temperature sensor, a stuck reversing valve, an outdoor fan motor that will not stop during defrost, or a low refrigerant charge. Do not chip at the ice: the fins and tubes are thin. Switch to emergency heat if the house is cold, and ask for a visit.
Blowing cool air all the time
If the vents blow cool air for long stretches and not just during defrost, the reversing valve may be stuck in cooling, or the compressor may not be running. Check that the thermostat is set to heat, not cool or auto with a low set point.
AUX on constantly
On a 40 degree day, a working heat pump should carry the house alone most of the time. If the strips run constantly, the heat pump may be low on refrigerant, the outdoor coil may be dirty or hail-damaged, or the thermostat may be wired or set up so the strips come on too early.
Outdoor unit will not start
The same capacitor, contactor and breaker failures that stop an air conditioner in July stop a heat pump in January. Check the breaker and the outdoor disconnect. If the unit hums without starting, switch it off and switch the thermostat to emergency heat until the contractor arrives.
Strips not working
Backup strips have their own breakers, often two, in the main panel or the air handler. A strip heater with a burned element or a tripped limit switch only shows itself on the cold nights when it is needed. Ask for the strips to be tested in the pre-season visit.
What to check before the contractor comes
- Thermostat on heat, not cool or auto; set point only a couple of degrees above the room
- Filter clean: low airflow also raises pressures and trips safeties
- Outdoor unit clear of snow, ice, leaves and anything leaning on it
- Breakers for the outdoor unit and the air handler, including the strip heat breakers
- Note what the thermostat displays: AUX, EM, a code, or a blank screen
Heat pump, dual fuel or furnace: thinking ahead
If your heat pump is old and the repair is large, the replacement question opens up. A dual fuel system keeps a heat pump for the many mild days and uses a gas furnace below a set outdoor temperature, which suits a city whose January averages are mild but whose cold snaps are sharp. The comparison table on the heating and air Oklahoma City page sets the three options side by side. If the home already has a furnace that is failing, see furnace replacement Oklahoma City.
A heat pump is also your air conditioner, so cooling faults show up here too. The AC repair Oklahoma City page has a symptom table for the summer side.
Installing a new heat pump
A new heat pump should be sized from a load calculation for the house, not by matching the old unit’s tonnage. Ask how the contractor set the auxiliary heat lockout and, on dual fuel, the switchover temperature, and ask them to show you on the thermostat. A replacement is mechanical work that normally needs a permit; in Oklahoma City the contractor must be licensed with the state Construction Industries Board and registered with the city. Anyone opening the refrigerant circuit needs EPA Section 608 certification.
Heat pump iced over or running on strips all day? Send the request form and a local heating and air contractor can contact you.
Questions and answers
Why is steam coming off my heat pump?
That is usually a defrost cycle melting frost off the outdoor coil. It lasts a few minutes, the outdoor fan stops, and then heating resumes. It is normal in damp weather in the 20s and 30s.
Should I use emergency heat when it is very cold?
Not just because it is cold. The system brings on auxiliary heat by itself when it needs to. Emergency heat is for when the outdoor unit has failed or is iced solid, as a bridge until it is repaired.
What does AUX on the thermostat mean?
The backup electric strips are running alongside the heat pump. Short stretches on cold mornings are normal. AUX on most of the day in mild weather points to a problem.
Is a heat pump a good choice in Oklahoma City?
For most of the heating season, yes, since January lows average about 27 degrees. On the coldest nights it relies on backup heat, which is why some homes choose dual fuel with a gas furnace.
Who will repair my heat pump?
Oklahoma City Heating connects you with an independent local heating and air contractor, who diagnoses the system and quotes the repair directly to you.